Only if the two sludges are close enough in filtration behavior. One press can handle both when cloth type, pressure profile, cycle times, and conditioning chemistry largely overlap. If they differ sharply, sharing a single plate pack usually means compromise on moisture, cycle length, or cloth life for at least one stream.
When sharing works
- Similar particle size and solids content after thickening
- Same or compatible polymer (or other conditioner) and dose range
- Comparable cake release and blinding tendency so one cloth grade works for both
- Overlapping fill and squeeze pressures (e.g., both run well in the typical 0.6–1.6 MPa range)
- You can accept a single moisture target and cycle time that suits the harder of the two
In that case a program-controlled chamber or membrane filter press can switch between feeds with only recipe changes (feed pressure ramp, squeeze time, wash interval).

When it usually fails
- One sludge is fine, colloidal, or highly compressible; the other is coarse and fast-filtering
- Conditioning chemistry conflicts (e.g., high lime or ferric on one stream blinds the cloth used for the other)
- Moisture limits differ a lot — one needs a membrane squeeze to 50–55%, the other is fine at 65–70%
- One stream is aggressive (chloride, solvent, high temperature) and needs stainless steel or special cloth the other does not justify
Running both on one machine then tends to produce longer cycles, wetter cake, or rapid cloth blinding on the more difficult sludge.
Practical approach
- Pilot or lab filter both sludges on the same cloth and plate type you plan to buy.
- Record fill time, pressure curve, cake moisture, and release.
- If the curves and moisture stay within an acceptable band, one press with two recipes is workable.
- If not, either dedicate the press to the harder stream, add a second smaller machine, or accept that one product will be off-spec.
At DZ Environmental we engineer both program-controlled chamber and automatic membrane filter presses. When two streams must share equipment, we size and set recipes from test data on both feeds rather than assuming interchangeability. If you can describe the two sludges (source, solids %, conditioning, and target moisture), the fit can be judged more tightly.